6 Commissioning
6/1
6.1 Range of applications:
• MIG/MAG welding (only in combination with an additional wire feed unit) for
steel-CrNi ∅ 0.8mm to 1.6mm,
aluminium ∅ 1.0mm to 1.6mm and
cored wires ∅ 0.9mm to 1.2mm.
6.1.1 Proper usage
These welding machines are only suitable for MIG/MAG welding.
Any other use is regarded as "improper" and no liability is assumed for any damage arising
therefrom.
We can only guarantee smooth and trouble-free operation of the machines when used in
conjunction with the welding torches and accessories from our range.
6.2 Setting up the welding machine
Follow the safety instructions on the opening pages entitled "For Your Safety".
Set up the machine so that there is sufficient space to adjust the operating elements.
Ensure that the machine is set up in a stable position and appropriately secured.
6.3 Mains connection
The correct mains plug must be connected to the mains supply lead on the machine. The
connection must be made by an electrician in compliance with current VDE regulations.
The phase sequence is irrelevant and has no effect on the direction of rotation of the fan
and pump, where applicable.
For mains fuse protection, please refer to the technical data (chapter 1).
• Insert mains plug of the switched-off machine into the appropriate socket.
6.3.1 Reconnecting the mains voltage 400/415V on the control transformer
The Faston plug (arrow) must be set on the transformer according to the mains voltage.
(Factory setting 400V.)
The following labels are located at the rear of the machine (top nameplate) (e.g.: factory
setting 400)
400V
Netzanschluß-
spannung
Mains voltage
The current mains voltage configuration for the machine is given on this label.
Sample labels with special voltages are included with
each machine (see right).
If the mains voltage configuration is changed, the
corresponding label with the new mains voltage printed
on it must be affixed over the sticker (right-hand box) on
the rear of the machine.
230V 230V
400V 400V
415V
440V/460V
400V/415V
460V
500V 500V
___V ___V
Comentarios a estos manuales