2 Description of the system components
2/9
2.3.2 M100 control
t
t
0.5
1
1.5
2sec0sec
0sec 2sec
1.5
1
0.5
4
6
10
18
m/min
0
20
8
12
14
16
2
4
3
2
1
Fig.: 2/7 M100 control panel
1
"Wire-feed speed" rotary dial
for infinitely variable setting of wire-feed speed (1 - 20m/min)
2
t
0.5
1
1.5
2sec0sec
Rotary dial for "spot and interval times"
for infinitely variable setting of welding time (0 - 2s)
in "SPOT and INTERVAL" mode
3
"Operating mode" selector
non-latched; latched; spot or interval welding
4
t
0sec 2sec
1.5
1
0.5
"Pause time" rotary dial
for infinitely variable setting of pause time (0 – 2s)
in "INTERVAL" mode