4 Description of control M200 / M210 (optional)
4/10
4.6.5 Error messages on M210 display unit
4.6.5.1 Short-circuit fault in welding torch / workpiece
Signal light Short-circuit between wire electrode (or gas nozzle) and
workpiece
4.6.5.2 General error messages
Via error message shown on the display
Message on the display Possible cause Fault elimination
Both displays flashing
• Error situation as under
4.6.5.1
• Lift welding torch from the
workpiece
Error message
e.g. E1
• Error in the machine • Service situation
Error message
e.g.: E6
• WF case not connected
(decompact only)
• Cable breakage
• No data transfer to M200
control
• For decompact machine,
connect WF case.
• Check control lead for
damage
• Service situation
4.7 M110 (optional) digital V / A meter with hold function
4.7.1 Display of actual values during and after welding
The digital VA meter M110 is available as an option for control M100 or M200.
This display informs the welder of the current power and voltage values during the welding
operation. In addition, the last welding data for the welding current and voltage is saved on the
display (Hold function).